If you own or manage a hotel, aparthotel, guest house or serviced apartment block in London, the latest wiring rules are now in force. BS 7671:2018+A4:2026, known as Amendment 4 or the “Orange Book”, published on 15 April 2026. The previous version, BS 7671:2018+A2:2022+A3:2024, was withdrawn on 15 October 2026. Any new electrical design, installation or alteration should now follow the updated standard.
At London Property Inspections, we help hospitality and accommodation owners stay compliant, safe and insured. This guide explains the latest wiring rules, what has changed, what it means for your property and what to do next.
What Is BS 7671 Amendment 4?
BS 7671 is the UK standard for electrical installations. Also called the IET Wiring Regulations. Amendment 4 is not a new edition. It is a consolidated update to the 18th Edition, and it folds Amendment 3 (2024) into the main document instead of leaving it as a separate add-on.
The change was driven by how buildings now use electricity. Hotels increasingly run EV chargers, rooftop solar, battery storage and data-heavy guest technology. Amendment 4 updates rules to match.
Key Dates Every London Property Owner Should Know
| Date | What happened |
| 15 January 2026 | IET and BSI signed off the content |
| 15 April 2026 | Amendment 4 published and usable immediately |
| 15 October 2026 | Previous version withdrawn |
Since the withdrawal, new work should be designed and certified to Amendment 4. The six-month overlap that allowed either version has ended.
Latest Wiring Rules: Key Changes Explained
1. Battery energy storage now has its own chapter
A new chapter covers stationary secondary batteries, which are the battery systems used to store and supply power to an installation. Amendment 4 treats them as generating sets rather than simple loads. For hotels pairing solar panels with storage, or using batteries to cut peak electricity costs, installation design now needs to follow clearer, more specific requirements.
2. Wider scope, including Power over Ethernet
The scope of the Regulations has been extended to cover stationary batteries and Power over Ethernet (PoE). PoE is increasingly used for room controls, Wi-Fi access points, CCTV and smart lighting. Many modern hotels have far more low-voltage cabling than they did a decade ago, so these systems now sit within the standard.
3. Changes for parallel generation and solar
Requirements for installations where more than one source of supply is connected, such as the grid plus solar PV plus batteries, have been tightened. Consumer units and switchgear must be rated to cope with the combined supply arrangements. This matters for any London property that has added renewables since its original wiring was installed.
4. EV charging clarifications
Section 722 on electric vehicle charging has been refined. One clarification confirms that AFDDs (arc fault detection devices) are not required for circuits supplying certain EV charging equipment that conforms to the relevant BS EN 61851 standard and incorporates socket outlets. If you are adding guest charging bays, make sure your electrician is working to the updated text rather than older guidance.
5. Surge protection, earthing and other refinements
Further changes appear across the Regulations, including updates on surge protective devices, medical locations (Section 710), and functional earthing for ICT systems. Medical location changes will not affect most hotels, but the ICT and surge protection updates are relevant to properties with extensive networking and guest technology.
Does Amendment 4 Mean My Existing Wiring Is Now Non-Compliant?
No. An installation that complied with the edition in force when it was designed and installed is not automatically unsafe or unlawful just because the standard has been updated. Amendments apply to new work and alterations.
However, there are two practical points for London hospitality owners:
- Alterations must meet the new rules. If you refurbish a floor, add a battery system or extend circuits, that new work should comply with Amendment 4.
- Inspections reflect current good practice. When an inspector carries out an Electrical Installation Condition Report (EICR), they assess the installation’s safety against the standard and note any observations. Older installations may show up as lacking features that modern designs would include. That is not automatically a failure, but it is useful information when planning upgrades.
Why This Matters for Hotels and Serviced Accommodation
Electrical safety in hospitality carries higher stakes than in a typical home:
- Fire risk with sleeping occupants. Guests are often asleep and unfamiliar with escape routes, so electrical faults are a serious hazard.
- Legal duties. Hotel operators in England must comply with the Regulatory Reform (Fire Safety) Order 2005 and complete a fire risk assessment, and electrical condition is a key part of that assessment.
- Insurance. Insurers commonly expect evidence of regular electrical testing and competent installation work. Gaps in your records can complicate claims.
- Reputation. A power failure or electrical incident during peak season can damage reviews and bookings quickly.
- Short-term lets. Serviced apartments and holiday lets may also be covered by landlord electrical safety rules, depending on how they are let. It is worth checking your specific position.
What London Property Owners Should Do Now
Step 1: Check your records
Gather your most recent EICR, installation certificates and any minor works certificates. If you cannot find them, or they are more than five years old, arrange a fresh inspection. Five years is a common maximum interval for many commercial premises, though some properties need more frequent testing based on their use and condition.
Step 2: Plan upgrades with Amendment 4 in mind
If you are considering solar, battery storage, EV charging or a major refurbishment, make sure your contractor confirms they are designing to BS 7671:2018+A4:2026. Ask for this in writing in your quotation.
Step 3: Choose competent professionals
Use electricians registered with a recognised competent-person scheme such as NICEIC, NAPIT or ELECSA, and ask for evidence that they have completed Amendment 4 training. This is a straightforward question and a reputable contractor will answer it easily.
Step 4: Schedule inspections around your quiet periods
In London, occupancy can stay high year-round. Booking inspections and remedial work in lower-demand weeks reduces disruption to guests and revenue.
Step 5: Keep your documentation organised
Store certificates, test results and remedial work records in one place, digital if possible. Good records make insurance, licensing and fire risk assessment reviews far smoother.
How London Property Inspections Can Help
London Property Inspections supports hotels, guest houses, aparthotels and serviced accommodation providers across the capital. Our services include:
- Electrical Installation Condition Reports (EICRs) carried out with the updated standard in mind
- Pre-upgrade surveys for solar, battery storage and EV charging projects
- Compliance gap reviews to help you prioritise work by risk and budget
- Clear, jargon-free reports with observations ranked by urgency so you know what needs action now and what can wait
- Flexible scheduling to keep disruption to guests to a minimum
Whether you run a boutique 12-room hotel in Kensington or a large serviced apartment block in the City, our aim is the same: to keep your guests safe, your property compliant and your business protected.
The latest wiring rules under BS 7671 Amendment 4 reflect how modern London properties actually use electricity: batteries, renewables, EV charging and networked technology. For hotel and accommodation owners, the main message is simple. Make sure any new or altered work follows the current standard, keep your inspection records up to date, and use competent, properly trained professionals.
FAQs
What is BS 7671 Amendment 4?
BS 7671 Amendment 4 is the 2026 update to the 18th Edition of the IET Wiring Regulations, the UK standard for electrical installations. It was published on 15 April 2026 and consolidates earlier amendments into one document. It adds new rules for battery storage and Power over Ethernet and refines requirements for EV charging, solar and surge protection.
When did the latest wiring rules come into force?
Amendment 4 could be used immediately from 15 April 2026. The previous version, BS 7671:2018+A2:2022+A3:2024, was withdrawn on 15 October 2026. From that date, new electrical work should be designed and installed to Amendment 4.
Do I need to rewire my hotel because of Amendment 4?
No. Existing installations that met the standard in force when they were installed do not automatically need rewiring. Amendment 4 applies to new work and alterations. A qualified inspector can tell you through an EICR whether your installation is safe and whether upgrades are worth planning.
How often should a London hotel have an electrical inspection?
Many commercial premises, including hotels, are typically inspected at least every five years. Higher-risk or heavily used properties, or those with a poor previous report, may need more frequent checks. Your inspector will recommend an interval based on the condition and use of your installation.
Does Amendment 4 affect EV charging and solar installations?
Yes. Amendment 4 adds a dedicated chapter for battery storage, tightens requirements for installations with multiple supply sources such as solar and batteries, and clarifies rules for EV charging circuits. If you plan to add any of these to your property, ask your contractor to confirm they are working to BS 7671:2018+A4:2026.